Fig. 7: When tightening the screw in the bone use just enough force to avoid micro fractures of the bone by the screw thread. Each plate must be anchored by at least two screws on either side of the fracture [...] Follow the same procedure to insert and fasten the remaining screws. Follow the same sequence: first hole - first screw, second hole - second screw, on one fragment. Operationstechnik Surgical Technique 10 [...] mixed dentition and it is safe to use 1.5 mm microplates and screws. In order to minimize the risk of damaging tooth buds, short 3.5 or 4 mm screws are recommended. In children between 6 and 9 years of age
Martin osteosynthesis screws in the planned diameteres and lengths. ■ A screwdriver to fi t the planned osteosynthesis screws. ■ A twist drill suitable for the planned osteosynthesis screws. Osteosynthesis [...] from a single source ■ Various planning possibilities - Specifi c predetermination of the screw holes and the screws to be inserted (Ø 1.5 mm and Ø 2.0 mm) - Preventive elements ( e.g. vanishing metal structures) [...] and/or locking screws (Ø 2.0 mm) depending on the planning. Upon request and depending on the intraoperative conditions not every fi xation possibility in the implant has to be used with a screw. 90-433-02
Drill-Free Screws Drill-Free Screws 1,5 x 4,0 mm 25-668-04 25-678-04 1,5 x 5,0 mm 25-668-05 25-678-05 1,5 x 7,0 mm 25-668-07 25-678-07 Mini-Schrauben Mini-Schrauben Mini Screws Mini Screws 2,0 x 7,0 mm [...] reconstructive, preprosthetic procedures Screw sizes: 1.0 - 1.5 - 2.0 mm, low profile All sizes available as self tapping screws Selected sizes available as Drill-Free-Screws® Micro mesh in three convenient sizes [...] Schrauben Recommended screws Centre Drive® Cross Drive (selbsthaltend) (selbsthaltend) (self-retaining) (self-retaining) Mikro-Schrauben Mikro-Schrauben Micro Screws Micro Screws 1,0 x 3,0 mm 25-660-03
clear focus on Orbital Trauma Reconstruction Mesh cutter, malleable spatulas, Byrd Zygoma reduction screw • To be altered according to surgeon‘s preference • Compatible to all KLS Martin surgical instruments
wire) Recommended screws (Centre Drive® or maxDrive®) 25-872-05-09 maxDrive® mini screws 2.0 x 5 mm 25-872-07-09 maxDrive® mini screws 2.0 x 7 mm 25-662-05-09 Centre Drive® mini screws 2.0 x 5 mm 25-662-07-09 [...] 51-565-90-07 and 2 maxDrive® Drill-Free screws 2.0 x 7 mm ** Sterile packed distractor, including activation wrench 51-565-90-07 and 2 maxDrive® Drill-Free screws 2.0 x 7 mm 12 Rapid Palatal Expander (RPE) [...] 51-565-90-07 and 2 maxDrive® Drill-Free screws 2.0 x 7 mm ** Sterile packed distractor, including activation wrench 51-565-90-07 and 2 maxDrive® Drill-Free screws 2.0 x 7 mm 13 Rapid Palatal Expander (RPE)
Spindle incl. pin, 60 mm 51-623-60-09 Spindle incl. pin, 70 mm 51-623-70-09 Recommended screws Standard screws: 1.5 x 3.5 mm to 1.5 x 5 mm Emergency: 1.8 x 5 mm Drill-Free: 1.5 x 5 mm Patient screwdrivers [...] Item Number 20 mm 51-630-20-09 30 mm 51-630-30-09 Distraction length/turn 0.3 mm Recommended screws Standard screws: 1.5 x 3.5 mm to 1.5 x 5 mm Emergency: 1.8 x 5 mm Drill-Free: 1.5 x 5 mm Patient screwdrivers [...] Item Number 20 mm 51-632-20-09 30 mm 51-632-30-09 Distraction length/turn 0.6 mm Recommended screws Standard screws: 2.0 x 3.5 mm to 2.0 x 5 mm Emergency: 2.3 x 5 mm Drill-Free: 2.0 x 5 mm Patient screwdrivers
output of 160,000 lux. Reliable independent power supply just couldn’t be more mobile. 6 No visible screw connection, seamless cover glasses, integrated gaskets, innovative joining technology – the marLED® E [...] smooth surface design of the light head permits fast and reliable cleaning unimpeded by external screws. Flush front glasses with inte- grated gaskets prevent any capillary effect when applying detergents
implants. Drilling and marking guides Drilling and marking guides are used to predrill the planned screw holes and mark the osteotomy line at the previously planned position. 55 Implants The patient-specific [...] and its surface. The implants for radius and forearm reconstruction are fixated with smartDrive® screws. Application requires only few instruments. 6 Scan protocol: Radius | Forearm Reconstruction IPS
same position with the screws previously used. Additional screws are now inserted after drilling on the caudal and cranial side. Check and adjust the vector before placing two screws into the caudal vector [...] 25-457-07-91 9 Screws and twist drills for TRACK 1.0 mm Screwdrivers see folding page Micro screws Length Centre Drive® 4 mm 25-660-04-09 5 mm 25-660-05-09 6 mm 25-660-06-09 Emergency screws Length Centre [...] 0 or TRACK 1 plus distractor will be fixed by 1.5-mm maxDrive® screws. For screws and drill bits see page 9. 1.5-mm maxDrive® locking screw TRACK 1.0 with optional support plate 51-525-40-09 13 TRACK 1