3 mm x x Viti Mini autobloccanti maxDrive® unit(s)5 Viti di emergenza autobloccanti Viti Drill Free autobloccanti Cacciaviti e lame maxDrive® 1 Ø x lunghezza maxDrive® 2,0 x 4 mm 25-872-04-09 25-872-04-75 [...] 9 Ø x lunghezza maxDrive® 2,3 x 4 mm 25-873-44-09 25-873-44-75 2,3 x 5 mm 25-873-45-09 25-873-45-75 2,3 x 7 mm 25-873-47-09 25-873-47-75 2,3 x 9 mm 25-873-49-09 Ø x lunghezza maxDrive® 2,0 x 5 mm 25-879-05-09 [...] 1⁄1 Sistema ortognatico Arnett FAB: viti, cacciaviti, lame e frese Viti, cacciaviti, lame e frese maxDrive® da 2,0 mm 1 Acciaio inossidabile Titanio Quantità / unità per confezione Impianti in confezione
Flap Fix Kit estéril Tres placas de perfil bajo con dos agujeros y seis tornillos autoperforantes maxDrive® reunidas en un kit estéril aportan numerosas ventajas, tanto para el paciente como para el usuario: [...] (nº ref. 25-302-10-71) incluye: ■ 3 x placas micro de perfil bajo con 2 agujeros ■ 6 x tornillos maxDrive® de 1,5 mm, longitud 4,0 mm, autoperforantes 06.14 · 90-996-03-04 · Printed in Germany · Copyright
fissazione di fratture e lembi ossei cranici Tre placche a due fori con profilo piatto e sei viti maxDrive® autofilettanti fornite in un solo kit sterile comportano molteplici vantaggi, sia per il paziente [...] neurochirurgia (art. n. 25-302-10-71) contiene: ■ 3 x micro-placche Low Profile a due fori ■ 6 x viti maxDrive® da 1,5 mm, lunghezza 4,0 mm, autofilettanti Gebrüder Martin GmbH & Co. KG Una società di KLS Martin
fixation of cranial bone flaps and fractures Three 2-hole low profile plates and six self-drilling maxDrive® screws combined in a sterile kit offer a variety of advantages both to the patient as well as to [...] Flap Fix Kit (Art. No. 25-302-10-71) includes: ■ 3x 2-hole low profile micro plates ■ 6x 1.5 mm maxDrive® screws, 4.0 mm long, self-drilling Gebrüder Martin GmbH & Co. KG A company of the KLS Martin Group
Micro Viti Micro selbsthaltend self-retaining autobloqueantes autobloquante autoritentiva maxDrive® 1 STERILE R maxDrive® 1.2 x 3 mm 25-870-03-91 25-870-03-71 1.2 x 4 mm 25-870-04-91 25-870-04-71 1.2 x 5 mm [...] Screwdrivers and Blades Destornilladores y terminales Tournevis et lames Cacciaviti e lame Centre Drive® maxDrive® abgeflacht flattened aplanado aplati ribassato abgeflacht flattened aplanado aplati ribassato
self-retaining maxDrive® unit(s)5 Emergency Screws self-retaining Drill-Free Screws self-retaining Screwdrivers and Blades maxDrive® 1 STERILE R STERILE R STERILE R Ø x Length maxDrive® 2.0 x 4 mm 25-872-04-09 [...] 25-872-19-09 Ø x Length maxDrive® 2.3 x 4 mm 25-873-44-09 25-873-44-75 2.3 x 5 mm 25-873-45-09 25-873-45-75 2.3 x 7 mm 25-873-47-09 25-873-47-75 2.3 x 9 mm 25-873-49-09 Ø x Length maxDrive® 2.0 x 5 mm 25-879-05-09 [...] 1 1 1 1 1⁄1 Arnett FAB orthognathic system: screws, screwdrivers, blades and twist drills 2.0-mm maxDrive® Screws, Screwdrivers, Blades and Twist Drills 1 Stainless steel Titanium Quantity / units per package
including activating wrench 51-565-90-07 and 2 maxDrive® Drill-Free screws 2.0 x 7 mm ** sterile packed distractor, including activation wrench 51-565-90-07 and 2 maxDrive® Drill-Free screws 2.0 x 7 mm 1:1 scale [...] Screws self-retaining Ø x Length maxDrive® 1.5 x 3.5 mm 25-875-03-09 1.5 x 4 mm 25-875-04-09 1.5 x 5 mm 25-875-05-09 1.5 x 6 mm 25-875-06-09 1.5 x 7 mm 25-875-07-09 maxDrive® 1.5 mm 5 Emergency Screws se [...] self-retaining Ø x Length maxDrive® 1.8 x 3.5 mm 25-876-03-09 1.8 x 4 mm 25-876-04-09 1.8 x 5 mm 25-876-05-09 1.8 x 7 mm 25-876-07-09 Drill-Free-Screws self-retaining Ø x Length maxDrive® 1.5 x 4 mm 25-878-04-09
screws 1.5 x 5 mm 1 5 pcs. to 25-665-07-09 Centre Drive® screws 1.5 x 7 mm 1 5 pcs. (equivalent maxDrive® screws would also be correct) 25-402-99-07 Screwdriver handle 1 1 piece 25-430-98-07 Blade for [...] 51-580-85-07 51-575-90-07 51-500-90-07 25-402-99-07 Screwdriver handle 25-489-97-07 Blade for 1.5-mm maxDrive® screws 25-430-98-07 Blade for 1.5-mm Centre Drive® screws Application Patient screwdriver Adjustment [...] 1 fixation eyelet The entire set is designed for single use only ! To be modified using a 1.5-mm maxDrive® screwdriver 17 Retention plate connector Allows a direct attachment of 1.5- and 1.8-mm retention
septum severed. 6. Fixation of the implants The IPS® plates are secured to the maxilla with Ø 1.5-mm maxDrive® screws. At first only the screw holes of the mobilized maxilla have to be fixated. Preferably, [...] fixation holes). 4. Fixation of the implants The IPS® plates are fixed to the mandible with Ø 2.0-mm maxDrive® screws in the predrilled holes. For insertion of the posterior screws we recommend using an angulated