accumulated blood while retracting the aneurysmal sac during abdominal aortic aneurysm surgery. The Zeitlin retractor with retro-clamp offers three benefits in one solution: retraction of surrounding tissue [...] facilitates the operation essentially. Good exposure demands a retractor that has two functions: retraction of surrounding tissue, gut, colon and fat and the exposure of the pathological vessel. The idea [...] pathological aorta and stable retro-clamping of the artery. Zeitlin retractors with extended asymmetric blades offer utmost exposure of the operation field and hold back surrounding structures. Zeitlin retractors
(biseau) One cutting edge toothed, one cutting edge with a microtome blade. Serrated blades prevent the tissue from moving, knife blades ensure a precise, atraumatic cut without the tissue being squeezed [...] checked for breakages ■ The working ends must be checked for movement Lever for lower blade Lever for upper bladeBlade Fixing screw A speculum is a medical examination instrument which is primarily used [...] consideration: ■ The areas marked must be oiled ■ The cutting blades must be checked for damage ■ If necessary replace carbide cutting blades ■ A test cut can be carried out with Kirschner wire Forceps /
, two small curved soft tissue retractors (2x RT1) are placed by the two surgical assistants to retract the soft tissues of the upper lip. A mucosal incision is made from lateral to lateral incisor using [...] spreader to mobilize the osteotomized maxilla. Same procedure at the left side. Mx1 retractor OS6 blade osteotome Mx4S bone spreader short Mx4L bone spreader large L1® MI Orthognathics | MI Le Fort I Osteotomy: [...] gently placing small (RT1) and large (RT2) soft tissue retrac- tors by the surgical assistants to retract the soft tissues of the lower jaw. Using a 15 scalpel, the operating surgeon starts the mucosal incision
osteotomy. A saw blade with the following dimensions may be used: • Cutting width (thickness): 0.38 - 0.8 mm • Width of working blade: 9 - 15 mm • Length: 31 - 40 mm A 0.38 mm thick saw blade is recommended [...] will be lost. A saw blade with the thickness of 0.38 mm is recommended and the following blade dimensions can be used: • Cutting width (thickness): 0.38 - 0.8 mm • Width of working blade: 9 - 15 mm • Length: [...] will be lost. A saw blade with the thickness of 0.38 mm is recommended and the following blade dimensions can be used: • Cutting width (thickness): 0.38 - 0.8 mm • Width of working blade: 9 - 15 mm • Length:
15-922-40-07 fan, blade, flexible, 140 x 90 mm 1 15-922-32-07 Breisky, blade, 150 x 25 mm 1 15-921-51-07 Langenbeck, blade, 150 x 50 mm 1 15-921-10-07 blade, flexible, 160 x 50 mm 1 15-921-13-07 blade, flexible [...] 15-922-40-07 fan, blade, flexible, 140 x 90 mm 1 15-922-32-07 Breisky, blade, 150 x 25 mm 1 15-921-51-07 Langenbeck, blade, 150 x 50mm 1 15-921-10-07 blade, flexible, 160 x 50 mm 1 15-921-13-07 blade, flexible [...] 15-922-40-07 fan, blade, flexible, 140 x 90 mm 1 15-922-32-07 Breisky, blade, 150 x 25 mm 1 15-921-51-07 Langenbeck, blade, 150 x 50 mm 1 15-921-10-07 blade, flexible, 160 x 50 mm 1 15-921-13-07 blade, flexible
that they can be retracted ulnad. Bluntly dissect the flexor carpi radialis, flexor pollicis longus and any other muscles off the pronator quadratus, and with Langenbeck retractors retract them ulnad together [...] 2.0-mm smartDrive® core hole drill for smartDrive® screws Ø 2.5 mm ■ No contractions between saw blade and plate, safe transection of the periosteum ■ Atraumatic screw tip ■ Atraumatic screw head ■ Double [...] control after removing the saw guide. To perform the osteotomy without contractions between the saw blade and the mounted plate and to safely transect the periosteum, the Recos® bridge plate (26-166-75-09)
insertion, tightening, and removal of the screw ■ Direct transfer of force from the screwdriver blade to the screw ■ Optimal synergy of handling and force transfer ■ Color-coded single clip ■ Clear assignment [...] the dorsal veins of the hand and sensitive nerve branches. The extensor tendons are mobilized and retracted together with the loosely connected soft tissue, preferably without transecting the tendinous junction
Searched for retractable blade.